UGZS.M-KR is designed for charging aircraft onboard systems with medical oxygen at pressures of up to 350 kgf/cm².
The unified gas charging station equipment allows the following works:
- charging the station from an external source of compressed gas; - charging the on-board systems of aircraft from the station cylinders by bypassing and using a compressor; - pumping gas from one group of station cylinders to another.
The UGZS station is serviced by two specialists: a car driver and a specialist operator who has undergone special training. The station is not intended for use in an explosive environment.
Technical Specifications;Value
UGZS station capacity at ambient temperature +20°C and pressure 760 mmHg, not less than;120
Outlet gas working pressure, kgf/cm²;from 0.5 to 5.5
;30, 150, 230, 350
Outlet gas temperature at ambient temperature +50°C, °C, not more than;not more than +70
Working gas;Medical oxygen
Number of cylinders, pcs.;18
Capacity of one cylinder, L;40
Production capacities allow for large-unit assembly of up to 50 machines per year. Our own specialized service center provides a full cycle of technical support and professional repair of airfield and electro-gas equipment. We guarantee prompt service and ensure maximum operational readiness of your equipment.