Technical Specifications;Value
Rated output power, kVA;165
Mode “LOAD 3N ~400Hz 200V” power, kVA, not less than / line voltage, V current frequency, Hz / rated current, A phase sequence / number of channels, pcs.;60/197-208 400±1/111; A-B-C (direct) / 2
Mode “LOAD ~400Hz 37V” power, kVA, not less than / line voltage, V current frequency, Hz / rated current, A phase sequence / number of channels, pcs.;2x1.5/36±1 400±1/20; A-C-B (reverse) / 2
Mode “LOAD ~400Hz 120V” power, kVA, not less than / line voltage, V current frequency, Hz / rated current, A;7/115-119;400±1/65
Mode “ONBOARD NETWORK 24V” line voltage, V / rated current, A number of channels, pcs. / power per channel, kW;28.5/315 1/2 (2 left side, 1 right side)/15
Mode “START 24/48V” short-time power of 2 channels, kW rated / maximum (2 min.), A;15;500/1000
Mode “START VIA SHRA-250M” voltage, V, not less than / rated current, A number of channels, pcs. / power per channel, kW;28.5/250 2/7.5
Operating conditions of the unit;-40 to +50°C